MELSEC iQ-F series
Awarded the iF Design Award in 2016!
The German design award iF Design Award has a tradition of over 60 years and recognized all over the world. Next generation PLC MELSEC iQ-F series, developed from the user perspective to provide improved visual verification and prevent operation mistakes, was awarded the iF Design Award in 2016!
MELSEC iQ-F Series Lineup | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flagship model equipped with advanced built-in functions and diverse expandability |
Simplifying use with renewed expansion modules! FX5U is equipped with analog functions, communication and high-speed I/O, and can easily be expanded with expansion boards and adapters.
|
||||||||||||||||||
Compact body packed with diverse functions |
Simplifying use with renewed expansion modules! The expansion module compatible with FX5UC is compact and easy-to-use, and helps to downsize your system.
|
||||||||||||||||||
FX5UJ with excellent cost performance that can be used in any scene |
FX5UJ is equipped with various built-in functions to improve ease of use! FX5UJ has an SD memory card slot, built-in USB (Mini-B) connector, and built-in Ethernet port as a standard.
|
Powered I/O module
Model | Total No. of points |
No. of input/output points & Input/output type |
Connection type | Compatible CPU module | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | FX5U | FX5UC | FX5UJ | ||||||
AC power supply type | ||||||||||
FX5-32ER/ES | 32 points | 16 points | 24 V DC (sink/source) |
16 points | Relay | Screw terminal block | ○ | × | ○ | |
FX5-32ET/ES | Transistor (sink) | |||||||||
FX5-32ET/ESS | Transistor (source) | |||||||||
DC power supply type | ||||||||||
FX5-32ER/DS | 32 points | 16 points | 24 V DC (sink/source) |
16 points | Relay | Screw terminal block | ○ | * ○ |
× | |
FX5-32ET/DS | Transistor (sink) | |||||||||
FX5-32ET/DSS | Transistor (source) |
*: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
page topInput module
Model | Total No. of points |
No. of input/output points & Input/output type |
Connection type | Compatible CPU module | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | FX5U | FX5UC | FX5UJ | ||||||
FX5-8EX/ES | 8 points | 8 points | 24 V DC (sink/source) |
- | - | Screw terminal block | ○ | *1 ○ |
○ | |
FX5-16EX/ES | 16 points | 16 points | ||||||||
FX5-C16EX/D | 16 points | 16 points | 24 V DC (sink) |
- | - | Connector | *2 ○ |
○ | *2 ○ |
|
FX5-C16EX/DS | 24 V DC (sink/source) |
|||||||||
FX5-C32EX/D | 32 points | 32 points | 24 V DC (sink) |
|||||||
FX5-C32EX/DS | 24 V DC (sink/source) |
|||||||||
FX5-C32EX/DS-TS | 32 points | 32 points | 24 V DC (sink/source) |
- | - | Spring clamp terminal block | *2 ○ |
○ | *2 ○ |
*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.
Output module
Model | Total No. of points |
No. of input/output points & Input/output type |
Connection type | Compatible CPU module | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | FX5U | FX5UC | FX5UJ | ||||||
FX5-8EYR/ES | 8 points | - | - | 8 points | Relay | Screw terminal block | ○ | *1 ○ |
○ | |
FX5-8EYT/ES | Transistor (sink) | |||||||||
FX5-8EYT/ESS | Transistor (source) | |||||||||
FX5-16EYR/ES | 16 points | 16 points | Relay | |||||||
FX5-16EYT/ES | Transistor (sink) | |||||||||
FX5-16EYT/ESS | Transistor (source) | |||||||||
FX5-C16EYR/D-TS | 16 points | - | - | 16 points | Relay | Spring clamp terminal block | *2 ○ |
○ | *2 ○ |
|
FX5-C16EYT/D | 16 points | - | - | 16 points | Transistor (sink) | Connector | *2 ○ |
○ | *2 ○ |
|
FX5-C16EYT/DSS | Transistor (source) | |||||||||
FX5-C32EYT/D | 32 points | 32 points | Transistor (sink) | |||||||
FX5-C32EYT/DSS | Transistor (source) | |||||||||
FX5-C32EYT/D-TS | 32 points | - | - | 32 points | Transistor (sink) | Spring clamp terminal block | *2 ○ |
○ | *2 ○ |
|
FX5-C32EYT/DSS-TS | Transistor (source) |
*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.
Input/output module
Model | Total No. of points |
No. of input/output points & Input/output type |
Connection type | Compatible CPU module | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | FX5U | FX5UC | FX5UJ | ||||||
FX5-16ER/ES | 16 points | 8 points | 24 V DC (sink/source) | 8 points | Relay | Screw terminal block | ○ | *1 ○ |
○ | |
FX5-16ET/ES | Transistor (sink) | |||||||||
FX5-16ET/ESS | Transistor (source) | |||||||||
FX5-C32ET/D | 32 points | 16 points | 24 V DC (sink) | 16 points | Transistor (sink) | Connector | *2 ○ |
○ | *2 ○ |
|
FX5-C32ET/DSS | 24 V DC (sink/source) | Transistor (source) | ||||||||
FX5-C32ET/DS-TS | 32 points | 16 points | 24 V DC (sink/source) | 16 points | Transistor (sink) | Spring clamp terminal block | *2 ○ |
○ | *2 ○ |
|
FX5-C32ET/DSS-TS | Transistor (source) |
*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.
High-speed pulse input/output module
Model | Total No. of points |
No. of input/output points & Input/output type |
Connection type | Compatible CPU module | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | FX5U | FX5UC | FX5UJ | ||||||
FX5-16ET/ES-H | 16 points | 8 points | 24 V DC (sink/source) | 8 points | Transistor (sink) | Screw terminal block | *1 ○ |
*1 *2 ○ |
× | |
FX5-16ET/ESS-H | Transistor (source) |
*1: Supported in version 1.030 or later.
Analog input devices (A/D conversion)
Model | Input specifications | Compatible CPU module |
||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of channels | Item | Input voltage | Input current | FX5U | FX5UC | FX5UJ | ||||
FX5U CPU module | 2 ch | Input range |
0 to 10 V DC (input resistance 115.7 kΩ) |
- | - | - | - | |||
Resolution | 2.5mV | - | ||||||||
FX5-4AD-ADP | 4 ch | Input range |
-10 to +10 V DC (Input resistance 1 MΩ) |
-20 to +20 mA DC (Input resistance 250 Ω) |
○ Max. 4 units |
○ Max. 4 units |
○ Max. 2 units |
|||
Input characteristics, resolution |
Analog Input range |
Resolution | Analog Input range |
Resolution | ||||||
10 to 10 V | 625 μV | 0 to 20 mA | 1.25 μA | |||||||
0 to 5 V | 312.5 μV | 4 to 20 mA | 1.25 μA | |||||||
1 to 5 V | 312.5 μV | -20 to 20 mA | 2.5 μA | |||||||
-10 to 10 V | 1250 μV | |||||||||
FX5-4AD | 4 ch | Input range |
-10 to +10 V DC (Input resistance 400 kΩ or more) |
-20 to +20 mA DC (Input resistance 250 Ω) |
○ | *1 ○ |
○ | |||
Input characteristics, resolution |
Analog Input range |
Resolution | Analog Input range |
Resolution | ||||||
0 to 10 V | 312.5 μV | 0 to 20 mA | 625 nA | |||||||
0 to 5 V | 156.25 μV | 4 to 20 mA | 500 nA | |||||||
1 to 5 V | 125 μV | -20 to +20 mA | 625 nA | |||||||
-10 to +10 V | 312.5 μV | |||||||||
User range setting |
125 μV | User range setting |
500 nA | |||||||
FX5-8AD | 8 ch | Input range |
-10 to 10 V DC (Input resistance 1 MΩ) |
-20 to +20 mA DC (Input resistance 250 Ω) |
○ | *1 ○ |
○ | |||
Input characteristics, resolution |
Analog Input range |
Resolution | Analog Input range |
Resolution | ||||||
0 to 10 V | 312.5 μV | 0 to 20 mA | 625 nA | |||||||
0 to 5 V | 156.25 μV | 4 to 20 mA | 500 nA | |||||||
1 to 5 V | 125 μV | -20 to +20 mA | 625 nA | |||||||
-10 to +10 V | 312.5 μV | |||||||||
FX3U-4AD | 4 ch | Input range |
-10 to +10 V DC (input resistance 200 kΩ) |
-20 to +20 mA DC, 4 to 20 mA (Input resistance 250 Ω) |
*2 ○ Max. Max. 6 to 8 modules *3 |
*2 ○ Max. 6 units |
× | |||
Resolution | 0.32 mV (20 V×1/64000) |
1.25 μA (40 mA×1/32000) |
*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.
*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.
page topAnalog output devices (D/A conversion)
Model | Output specifications | Compatible CPU module |
||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of channels | Item | Output voltage | Output current | FX5U | FX5UC | FX5UJ | ||||
FX5U CPU module | 1 ch | Output range |
0 to 10 V DC (External load resistance value 2 kΩ to 1 MΩ) |
- | - | - | - | |||
Resolution | 2.5 mV | - | ||||||||
FX5-4DA-ADP | 4 ch | Output range |
-10 to +10 V DC (External load resistance value 1 kΩ to 1 MΩ) |
0 to 20 mA DC (External load resistance value 0 to 500 Ω) |
○ Max. 4 units |
○ Max. 4 units |
○ Max. 2 units |
|||
Output characteristics, resolution |
Analog Output range |
Resolution | Analog Output range |
Resolution | ||||||
0 to 10 V | 625 μV | 0 to 20 mA | 1.25 μA | |||||||
0 to 5V | 312.5 μV | |||||||||
1 to 5V | 250 μV | 4 to 20 mA | 1 μA | |||||||
-10 to 10 V | 1250 μV | |||||||||
FX5-4DA | 4 ch | Output range |
-10 to +10 V DC (External load resistance value 1 kΩ to 1 MΩ) |
0 to 20 mA DC (External load resistance value 0 to 500 Ω) |
○ | *1 ○ |
○ | |||
Output characteristics, resolution |
Analog Output range |
Resolution | Analog Output range |
Resolution | ||||||
0 to 10 V | 312.5 μV | 0 to 20 mA | 625 nA | |||||||
0 to 5 V | 156.3 μV | |||||||||
1 to 5 V | 125 μV | 4 to 20 mA | 500 nA | |||||||
-10 to +10 V | 312.5 μV | |||||||||
User range setting |
312.5 μV | User range setting |
500 nA | |||||||
FX3U-4DA | 4 ch | Output range |
-10 to +10 V DC (external load resistance value 1 kΩ to 1 MΩ) |
0 to 20 mA DC, 4 to 20 mA DC (External load resistance value 500 Ω or less) |
*2 ○ Max. 6 to 8 modules *3 |
*2 ○ Max. 6 units |
× | |||
Resolution | 0.32 mV (20 V × 1/64000) |
0.63 μA (20 mA × 1/32000) |
*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.
page topInput device for temperature sensor
Model | Number of channels | Available sensor | Input specifications | Compatible CPU module |
||||
---|---|---|---|---|---|---|---|---|
Item | Temperature input | FX5U | FX5UC | FX5UJ | ||||
FX5-4AD-PT-ADP | 4 ch | Usable resistance temperature detector Pt100 Ni100 |
Input range |
[Typical example] Pt100: -200 to +850˚C Ni100: -60 to +250˚C |
○ Max. 4 units |
○ Max. 4 units |
○ Max. 2 units |
|
Resolution | 0.1˚C | |||||||
FX5-4AD-TC-ADP | 4 ch | Thermocouple K, J, T, B, R, S |
Input range |
[Typical example] K type: -200.0 to 1200˚C J type: -40.0 to 750˚C |
○ Max. 4 units |
○ Max. 4 units |
○ Max. 2 units |
|
Resolution | 0.1 to 0.3˚C (depending on the sensor used) |
|||||||
FX5-8AD | 8 ch | Usable resistance temperature detector Pt100 Ni100 |
Input range |
[Typical example] Pt100: -200 to +850˚C Ni100: -60 to +250˚C |
○ | *1 ○ |
○ | |
Resolution | 0.1˚C | |||||||
Thermocouple K, J, T, B, R, S |
Input range |
[Typical example] K type: -270.0 to 1200˚C J type: -40.0 to 750˚C |
||||||
Resolution | 0.1 to 0.3˚C (depending on the sensor used) |
|||||||
FX5-4LC | 4 ch | Platinum resistance thermometer sensor Pt100, JPt100, Pt1000 |
Input range |
[Typical example] 3-wire Pt100: -200 to 600˚C 3-wire JPt100: -200 to 500˚C 2-wire/3-wire Pt1000: -200.0 to 650.0˚C |
○ | *1 ○ |
○ | |
Resolution | 0.1˚C or 1˚C (depending on the sensor used) |
|||||||
Thermocouple K, J, R, S, E, T, B, N JIS C 1602-1995, PLII, W5Re/W26Re, U, L |
Input range |
[Typical example] K type: -200.0 to 1300˚C J type: -200.0 to 1200˚C |
||||||
Resolution | 0.1˚C or 1˚C (depending on the sensor used) |
|||||||
Micro voltage input | Input range |
0 to 10 mV DC 0 to 100 mV DC |
||||||
Resolution | 0.5 μV or 5.0 μV (depending on the sensor used) |
|||||||
FX3U-4LC | 4 ch | Platinum resistance thermometer sensor Pt100, JPt100, Pt1000 |
Input range |
[Typical example] 3-wire Pt100: -200 to 600˚C 2-wire/3-wire Pt1000: -200.0 to 650.0˚C |
*2 ○ Max. 6 to 8 modules *3 |
*2 ○ Max. 6 units |
× | |
Resolution | 0.1˚C or 1˚C (depending on the sensor used) |
|||||||
Thermocouple K/J/R/S/E/T/B/ N/PLII/W5Re/ W26Re/U/L type |
Input range |
[Typical example] K type: -200.0 to 1300˚C J type: -200.0 to 1200˚C |
||||||
Resolution | 0.1˚C or 1˚C (depending on the sensor used) |
|||||||
Low voltage input | Input range |
0 to 10 mV DC 0 to 100 mV DC |
||||||
Resolution | 0.5 μV or 5.0 μV (depending on the sensor used) |
*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.
*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.
High speed counter
Model | Number of channels | Type | Highest response frequency |
Hardware comparison output function |
2-phase counter edge count function |
Compatible CPU module | |||
---|---|---|---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||||||
FX3U-2HC | 2 ch | 1 phase 1 input |
Max. 200 kHz | ○ | - | * ○ Up to 2 modules |
* ○ Up to 2 modules |
× | |
1 phase 2 input |
Max. 200 kHz | ||||||||
2 phase 2 input |
1 edge count: Max. 200 kHz 2 edge count: Max. 100 kHz 4 edge count: Max. 50 kHz |
○ |
*: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
page topHigh-speed pulse input/output module
Model | Generic Specifications | Function | Compatible CPU module | |||
---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | ||||
FX5-16ET/ES-H | Max. 2 ch 200 kHz | High-speed counter function - Normal mode Pulse Width Measurement Function Pulse Catch Function General-purpose Input Functions |
*1 ○ Up to 4 modules |
*1*2 ○ Up to 4 modules |
× | |
FX5-16ET/ESS-H |
*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
FX5U/FX5UC/FX5UJ CPU module built-in input functions (Built-in high-speed counter function)
Model | Generic Specifications | Function | |
---|---|---|---|
FX5U CPU module | Max. 8ch 200kHz FX5U-32M: 6 ch 200kHz + 2 ch 10kHz |
High-speed counter function - Normal mode - Pulse density measurement mode - Rotation speed measurement mode FX3-compatible high-speed counter function Pulse Width Measurement Function Pulse Catch Function - Pulse Catch Function - FX3-Compatible Pulse Catch Function General-purpose Input Functions |
|
FX5UC CPU module | Max. 8 ch 200kHz FX5UC-32M: 6 ch 200kHz + 2 ch 10kHz |
||
FX5UJ CPU module | Max. 4 ch 100kHz + 4 ch 10 Hz |
Simple Motion Module (SSCNET III/H)
Model | Number of control axes | Main functions/Control | Compatible CPU module | |||
---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | ||||
FX5-40SSC-S | 4 axes | Function Linear interpolation Circular interpolation Continuous trajectory control S-curve acceleration/deceleration Control Synchronous control Cam control Torque control |
○ Up to 16 modules |
*1 ○ Up to 8 modules |
*2 ○ Up to 1 modules |
|
FX5-80SSC-S | 8 axes | Function Linear interpolation Circular interpolation Continuous trajectory control S-curve acceleration/deceleration Control Synchronous control Cam control Torque control |
○ Up to 16 modules |
*1 ○ Up to 8 modules |
*2 ○ Up to 1 modules |
*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: FX5-40SSC-S and FX5-80SSC-S cannot be used together.
High-speed pulse input/output module
Model | Number of control axes | Maximum frequency | Compatible CPU module | |||
---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | ||||
FX5-16ET/ES-H | 2 axes | 200 kpps | *1 ○ Up to 4 modules |
*1 *2 ○ Up to 4 modules |
× | |
FX5-16ET/ESS-H |
*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
Positioning module
Model | Number of control axes | Maximum frequency | Compatible CPU module | |||
---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | ||||
FX5-20PG-P | 2 axes | 200 kpps | ○ | *1 ○ |
○ | |
FX5-20PG-D | 2 axes | 5 Mpps | ○ | *1 ○ |
○ | |
FX3U-1PG | 1 axis | 200 kpps | *2 ○ Max. 6 to 8 modules *3 |
*2 ○ Max. 6 modules |
× |
*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.
*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.
page topFX5U/FX5UC/FX5UJ CPU module built-in output functions (Built-in positioning function)
Model | Generic Specifications | Function | |
---|---|---|---|
FX5U CPU module | Max. 200 kHz 4 axes *Supported by transistor output type CPU module |
JOG operation (Supported by variable speed operation) Machine home position return Fast home position return control 1-speed positioning 2-speed positioning Multi-speed operation Interrupt stop Interrupt and 1-speed positioning Interrupt and 2-speed positioning Variable speed operation Simple linear interpolation (Start 2-Axis simultaneously) Table operation Absolute position detection system |
|
FX5UC CPU module | |||
FX5UJ CPU module | Max. 200 kHz 3 axes *Supported by transistor output type CPU module |
CC-Link IE field network
Model | Master station function | Remote, slave function |
Distance | Compatible CPU module | |||
---|---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||||
FX5-CCLIEF CC-Link IE field network (Intelligent device station) |
× | ○ | 100 m | *1 ○ Up to 1 module |
*1 *2 ○ Up to 1 module |
○ Up to 1 module |
*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
CC-Link
Model | Master station function | Remote, slave function |
Distance | Compatible CPU module | |||
---|---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||||
FX5-CCL-MS CC-Link system master/intelligent device module |
○ | ○ | 1200 m | ○ | *1 ○ |
○ | |
FX3U-16CCL-M *2 CC-Link (Master station) |
○ | × | 1200 m | *3 ○ Up to 1 module |
*3 ○ Up to 1 module |
× | |
FX3U-64CCL CC-Link (Intelligent device station) |
× | ○ |
*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.
*2: When CC-Link master and AnyWire Bitty master or AnyWireASLINK master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASLINK master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user's manuals.
*3: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
page topEthernet
Model | Data transmission speed |
Maximum segment length |
Supported protocol | No. of connections | |
---|---|---|---|---|---|
FX5U CPU module | 100 / 10 Mbps | 100 m (The distance between hub and node) |
CC-Link IE field network Basic FTP Server SNTP client Web server (HTTP) Simple CPU communication function MELSOFT connection SLMP (3E frame) Socket communication Predefined protocol support MODBUS/TCP communication |
Total of 8 connections*1*2 (Up to 8 external devices are accessible to one CPU module at a time.) |
|
FX5UC CPU module | |||||
FX5UJ CPU module | |||||
FX5-ENET Ethernet module |
CC-Link IE field network Basic |
Total of 32 connections*3 (Up to 32 external devices are accessible to one FX5-ENET at a time.) |
|||
FX5-ENET/IP EtherNet/IP module |
EtherNet/IP |
Total of 32 connections (Up to 32 external devices are accessible to one FX5-ENET/IP at a time.) |
*1: The first device for MELSOFT connection is not included in the number of connections. (The second and the following devices are included.)
*2: The CC-Link IE field network Basic, FTP server, SNTP client, Web server and simple CPU communication function are not included in the number of connections.
*3: The CC-Link IE field network Basic are not included in the number of connections.
page topEtherNet/IP
Model | Data transmission speed |
Maximum segment length |
Supported protocol | Compatible CPU module | |||
---|---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||||
FX5-ENET/IP EtherNet/IP module |
100 / 10 Mbps | 100 m (The distance between hub and node) |
Class 1 communications |
○ Up to 1 module |
*1 ○ Up to 1 module |
○ Up to 1 module |
*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
page topPROFIBUS-DP
Model | Transmission protocol | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX5-DP-M PROFIBUS-DP Master module |
PROFIBUS-DP | ○ Up to 1 module |
*1 ○ Up to 1 module |
○ Up to 1 module |
*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
page topSensor Solution
Model | Transmission protocol | Number of connected I/O points | Compatible CPU module | |||
---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | ||||
FX5-ASL-M AnyWireASLINK system master module |
Dedicated protocol (AnyWireASLINK) |
448 points maximum *1*2*3 (input: maximum 256 points, output: maximum 256 points) |
○ Up to 1 module |
*4 ○ Up to 1 module |
○ Up to 1 module |
|
FX3U-128BTY-M *5 AnyWire Bitty series master |
Dedicated protocol (AnyWire Bitty) |
Up to 128 points | *6 ○ Up to 1 module |
*6 ○ Up to 1 module |
× | |
FX3U-128ASL-M *5 AnyWireASLINK system master |
Dedicated protocol (AnyWireASLINK) |
*1: The number of available remote I/O points per system varies depending on the number of I/O points of the extension devices.
*2: The maximum number of points that can be used differs depending on the version of the CPU module used.
*3: When connecting to the FX5UJ CPU module, the maximum is 216 points (input: maximum 192 points, output: maximum 192 points).
*4: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.
*5: When CC-Link master and AnyWire Bitty master or AnyWireASLINK master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASLINK master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user's manuals.
*6: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
page topMODBUS communication
Model | Communication interface | Maximum transmission distance | Generic Specifications | Compatible CPU module | |||
---|---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||||
FX5-232-BD | RS-232C | 15 m | Predefined protocol: RTU No. of connectable slaves: 1 |
○ Up to 1 modules |
× | ○ Up to 1 modules |
|
FX5-232ADP | ○ Up to 2 modules |
○ Up to 2 modules |
○ Up to 2 modules |
||||
FX5U CPU module | RS-485 | 50 m | Predefined protocol: RTU No. of connectable slaves: 32 |
- | - | - | |
FX5UC CPU module | - | - | - | ||||
FX5-485-BD | 50 m | ○ Up to 1 module |
× | ○ Up to 1 module |
|||
FX5-485ADP | 1200 m | ○ Up to 2 module |
○ Up to 2 module |
○ Up to 2 module |
Serial communication
Model | Communication interface | Maximum transmission distance | Function type | Compatible CPU module | |||
---|---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||||
FX5-232-BD | RS-232C | 15 m | MELSOFT connection MELSEC Communication protocol (1C/3C/4C frames) Non-protocol communication Predefined protocol support |
○ Up to 1 module |
× | ○ Up to 1 module |
|
FX5-232ADP | ○ Up to 2 module |
○ Up to 2 module |
○ Up to 2 module |
||||
FX5U CPU module | RS-485 | 50 m | MELSOFT Connection MELSEC Communication protocol (1C/3C/4C frames) Non-protocol communication Inverter communication N:N network Parallel link Predefined protocol support |
- | - | - | |
FX5UC CPU module | - | - | - | ||||
FX5-485-BD | 50 m | ○ Up to 1 module |
× | ○ Up to 1 module |
|||
FX5-485ADP | 1200 m | ○ Up to 2 module |
○ Up to 2 module |
○ Up to 2 module |
|||
FX5-422-BD-GOT | RS-422 | As per GOT specifications | GOT connection | ○ Up to 1 module |
- | ○ Up to 1 module |
Safety main module
Item | Total No. of points | Safety inputs | Safety outputs | Safety integrity level (SIL) | Performance level (PL) | Off delay time | Built-in program | Connection type | Compatible CPU module | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | ||||||||||
FX5-SF-MU4T5 | 8 points | 4 points | 4 points | SIL3 (IEC 61508) | PL e (DIN EN ISO 13849-1) | 0 / 0.5 / 1 /1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 5 s | 9 types | Spring clamp terminal block | ○ | * ○ |
× |
*: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
page topSafety expansion module
Safety input expansion module
Item | Total No. of points | Safety inputs | Safety outputs | Safety integrity level (SIL) | Performance level (PL) | Off delay time | Built-in program | Connection type | Compatible CPU module*3 | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | ||||||||||
FX5-SF-8DI4 | 8 points | 8 points | 0 points | SIL3 (IEC 61508) | PL e (DIN EN ISO 13849-1) | *1 | *2 9 types |
Spring clamp terminal block | ○ | *4 ○ |
× |
*1: Set the off delay time in the safety main module.
*2: The built-in program can set the logical path connection method with the safety main module for INPUT A and INPUT B each.
*3: Safety main module is required to connect to the CPU modules.
*4: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
Extension power supply module
Model | Specifications | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX5-1PSU-5V | Power supply for FX5 extension module Internal 5V DC: 1.2 A *1 Internal 24 V DC: 0.3 A *1 |
○ (AC power supply type) Up to 2 modules *3 |
× | ○ Up to 1 module |
|
FX3U-1PSU-5V | Power supply for FX3 extension module Internal 5 V DC: 1 A *1 Internal 24 V DC: 0.3 A *1 |
*2 ○ (AC power supply type) Up to 2 modules *3 |
× | × | |
FX5-C1PS-5V | Power supply for FX5 extension module [Output current] 5 V DC: 1200 mA *1 24 V DC: 625 mA *1 |
*4 |
○ Up to 2 modules |
× |
*1: Maximum output current depends on the ambient temperature.
*2: When connecting to FX5U, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
*3: Max. of total two FX5-1PSU-5V and FX3U-1PSU-5V can be connected in one system.
*4: When connecting to FX5U, FX5-CNV-IF is required.
Connector conversion module
Model | Specifications | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX5-CNV-IF | Connector conversion module used from FX5 (extension cable type) to connect FX5 (extension connector type) extension modules. Control power: not consumed |
○ Up to 1 module |
× | ○ Up to 1 module |
|
FX5-CNV-IFC | Connector conversion module used from FX5 (extension connector type) to connect FX5 (extension cable type) extension modules. Control power: not consumed |
× | ○ Up to 1 module |
× |
Connector conversion adapter
Model | Specifications | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX5-CNV-BC | Connector conversion adapter | ○ Up to 1 module |
○ Up to 1 module |
○ Up to 1 module |
Extension cable
Model | Length | Application | Compatible CPU module | |||
---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | ||||
FX5-30EC | 0.3m | Extension cable for extension module | ○ Up to 1 module |
○ Up to 1 module |
○ Up to 1 module |
|
FX5-65EC | 0.65m |
Bus conversion module
Model | Specifications | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX5-CNV-BUS | Bus conversion FX5 (extension cable type) -> FX3 extension Control power: 5 V DC 150 mA (supplied from PLC) |
○ Up to 1 module |
*1 ○ Up to 1 module |
× | |
FX5-CNV-BUSC | Bus conversion FX5 (extension connector type) -> FX3 extension Control power: 5 V DC 150 mA (supplied from PLC) |
*2 ○ Up to 1 module |
○ Up to 1 module |
× |
*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to FX5UC.
*2: FX5-CNV-IF is necessary to connect to FX5U.
Terminal modules
Terminal modules are used to convert connector-type I/O terminals into terminal blocks.
By using terminal blocks (built-in element type) dedicated to input or output, capturing of AC input signals and format conversion into the relay/transistor/triac output can be performed.
Model | No. of input points |
No. of output points |
Function | |
---|---|---|---|---|
FX-16E-TB | 16 input points or 16 output points | Directly connected to the I/O terminal of PLC. Using this unit instead of a terminal block or relaying a wiring of I/O device located remotely from PLC enables reducing of the man-hours of I/O wiring. |
||
FX-16E-TB/UL | ||||
FX-32E-TB | 32 input points, 32 output points, or 16 input points and 16 output points |
|||
FX-32E-TB/UL | ||||
FX-16EYR-TB | - | 16 points | Relay output type | |
FX-16EYR-ES-TB/UL | ||||
FX-16EYS-TB | Triac output type | |||
FX-16EYS-ES-TB/UL | ||||
FX-16EYT-TB | Transistor output type (sink) | |||
FX-16EYT-ES-TB/UL | ||||
FX-16EYT-ESS-TB/UL | Transistor output type (source) |
SD memory card
Model | Specifications | Compatible CPU module | ||||
---|---|---|---|---|---|---|
Type | Capacity | Number of writes | FX5U | FX5UC | FX5UJ | |
NZ1MEM-2GBSD | SD memory card | 2G bytes | 60,000 times | ○ Up to 1 module |
○ Up to 1 module |
○ Up to 1 module |
NZ1MEM-4GBSD | SDHC memory card | 4G bytes | 100,000 times | |||
NZ1MEM-8GBSD | 8G bytes | |||||
NZ1MEM-16GBSD | 16G bytes |
Battery
Model | Application | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX3U-32BL | The battery will be used when you desire to retain (latch) * the status of the device memory or clock data before a power failure. At the time of delivery from a plant, the battery is not built in the CPU module. Please make arrangements if required. |
○ Up to 1 module |
○ Up to 1 module |
× |
*: Setting of parameter is required for a power failure retention.
page topCable
Model | Length | Application | |
---|---|---|---|
FX-232CAB-1 | 3.0 m | Use a communication cable to connect a PLC with a personal computer by RS-232C communication. FX5-232ADP <-> Personal computer FX5-232-BD * <-> Personal computer |
*: FX5-232-BD can be connected to the FX5U/FX5UJ CPU module.