Your Position: Home > Product > Mitsubishi

PLC Splitter Melsec Iq-F Series Lineup Fx5u or Fx5UC, Fx5-Cnv-Bus or Fx5-Cnv-Busc

Update: 2020/12/14      View:
  • Brand:    Mitsubishi
  • Type:    fx3u-128MR/ES-A
  • Price:    3200 RMB
  • Promotion:    2600 RMB ( 0 Customers Bought)
  • Order Online   Add to favorites
Introduction

MELSEC iQ-F series

PLC Splitter Melsec Iq-F Series Lineup Fx5u or Fx5UC, Fx5-Cnv-Bus or Fx5-Cnv-Busc
 

Awarded the iF Design Award in 2016!
The German design award iF Design Award has a tradition of over 60 years and recognized all over the world. Next generation PLC MELSEC iQ-F series, developed from the user perspective to provide improved visual verification and prevent operation mistakes, was awarded the iF Design Award in 2016!
 

MELSEC iQ-F Series Lineup
Flagship model equipped with advanced built-in functions and diverse expandability
PLC Splitter Melsec Iq-F Series Lineup Fx5u or Fx5UC, Fx5-Cnv-Bus or Fx5-Cnv-Busc




 

Simplifying use with renewed expansion modules!

FX5U is equipped with analog functions, communication and high-speed I/O, and can easily be expanded with expansion boards and adapters.
The high-speed system bus communication brings out the maximum performance of expansion devices equipped with intelligent functions.

Control scale 32 to 384 points (CPU module: 32/64/80 points)
Max. 512 pts including CC-Link, AnyWireASLINK, and Bitty series remote I/O
Program memory 128 k steps (Comment and statements in separate area)
Built-in analog input/output A/D 2 ch 12-bit
D/A 1 ch 12-bit
Built-in SD Memory Card Slot Max. 16 GB (SD/SDHC memory card)
[Application]
Stores device comment file and folders/files created by functions using SD memory card.
Built-in Ethernet Port 10BASE-T/100BASE-TX
[Application]
  • Socket communication (Direct connection to other PLCs)
  • Remote maintenance (Read/write program with GX Works3 connected via VPN)
  • SLMP Communication (Read/write PLC device data from PC)
Built-in RS-485 port Conforming to RS-485 and RS-422 standards
[Application]
  • Inverter Communication (Max. length 50 m, max. 16 units can be connected)
  • MODBUS® Communication (Up to 32 devices can be connected, including other PLCs, sensors, temperature controllers)
Built-in
input/output
function
Built-in positioning 4 axes 200 kHz pulse output
Built-in
high-speed counter
Max. 8 ch 200 kHz high speed pulse input
(FX5U-32M: 6 ch 200 kHz + 2 ch 10 kHz)
Compact body packed with diverse functions
PLC Splitter Melsec Iq-F Series Lineup Fx5u or Fx5UC, Fx5-Cnv-Bus or Fx5-Cnv-Busc




 

Simplifying use with renewed expansion modules!

The expansion module compatible with FX5UC is compact and easy-to-use, and helps to downsize your system.
Easily connect to the FX5 and FX3 expansion modules with the variety of conversion modules available.

Control scale 32 to 384 points (CPU module: 32/64/96 points)
Max. 512 pts including CC-Link, AnyWireASLINK, and Bitty series remote I/O
Program memory 128 k steps (Comment and statements in separate area)
Built-in SD Memory Card Slot Max. 16 GB (SD/SDHC memory card)
[Application]
Stores device comment file and folders/files created by functions using SD memory card.
Built-in Ethernet Port 10BASE-T/100BASE-TX
[Application]
  • Socket communication (Direct connection to other PLCs)
  • Remote maintenance (Read/write program with GX Works3 connected via VPN)
  • SLMP Communication (Read/write PLC device data from PC)
Built-in RS-485 port Conforming to RS-485 and RS-422 standards
[Application]
  • Inverter Communication (Max. length 50 m, max. 16 units can be connected)
  • MODBUS® Communication (Up to 32 devices can be connected, including other PLCs, sensors, temperature controllers)
Built-in
input/output
function
Built-in positioning 4 axes 200 kHz pulse output
Built-in
high-speed counter
Max. 8 ch 200 kHz high speed pulse input
(FX5UC-32M: 6 ch 200 kHz + 2 ch 10 kHz)
FX5UJ with excellent cost performance that can be used in any scene
PLC Splitter Melsec Iq-F Series Lineup Fx5u or Fx5UC, Fx5-Cnv-Bus or Fx5-Cnv-Busc




 

FX5UJ is equipped with various built-in functions to improve ease of use!

FX5UJ has an SD memory card slot, built-in USB (Mini-B) connector, and built-in Ethernet port as a standard.
In addition, built-in functions such as positioning and highspeed counters are included to condense various functions and ease of use.

Control scale 24 to 256 points (CPU module: 24/40/60 points)
Max. 256 pts including CC-Link, AnyWireASLINK, and Bitty series remote I/O
Program memory 48 k steps (Comment and statements in separate area)
Built-in SD Memory Card Slot Max. 16 GB (SD/SDHC memory card)
[Application]
Stores device comment file and folders/files created by functions using SD memory card.
Built-in Ethernet Port 10BASE-T/100BASE-TX
[Application]
  • Socket communication (Direct connection to other PLCs)
  • Remote maintenance (Read/write program with GX Works3 connected via VPN)
  • SLMP Communication (Read/write PLC device data from PC)
Built-in USB connector Mini-B (Data transfer speed: Max. 12 Mbps)
[Application]
Connections with GX Works3 can be established with just a single cable.
Built-in
input/output
function
Built-in positioning 3 axes 200 kHz pulse output
Built-in
high-speed counter
4 ch 200 kHz + 4 ch 10 kHz high speed pulse input
 

Powered I/O module

Model Total No.
of points
No. of input/output points
& Input/output type
Connection type Compatible CPU module
Input Output FX5U FX5UC FX5UJ
AC power supply type
  FX5-32ER/ES 32 points 16 points 24 V DC
(sink/source)
16 points Relay Screw terminal block ×
FX5-32ET/ES Transistor (sink)
FX5-32ET/ESS Transistor (source)
DC power supply type
  FX5-32ER/DS 32 points 16 points 24 V DC
(sink/source)
16 points Relay Screw terminal block *
×
FX5-32ET/DS Transistor (sink)
FX5-32ET/DSS Transistor (source)

*: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page top

Input module

Model Total No.
of points
No. of input/output points
& Input/output type
Connection type Compatible CPU module
Input Output FX5U FX5UC FX5UJ
  FX5-8EX/ES 8 points 8 points 24 V DC
(sink/source)
- - Screw terminal block *1
  FX5-16EX/ES 16 points 16 points
  FX5-C16EX/D 16 points 16 points 24 V DC
(sink)
- - Connector *2
*2
FX5-C16EX/DS 24 V DC
(sink/source)
  FX5-C32EX/D 32 points 32 points 24 V DC
(sink)
FX5-C32EX/DS 24 V DC
(sink/source)
  FX5-C32EX/DS-TS 32 points 32 points 24 V DC
(sink/source)
- - Spring clamp terminal block *2
*2

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.

page top

Output module

Model Total No.
of points
No. of input/output points
& Input/output type
Connection type Compatible CPU module
Input Output FX5U FX5UC FX5UJ
  FX5-8EYR/ES 8 points - - 8 points Relay Screw terminal block *1
FX5-8EYT/ES Transistor (sink)
FX5-8EYT/ESS Transistor (source)
  FX5-16EYR/ES 16 points 16 points Relay
FX5-16EYT/ES Transistor (sink)
FX5-16EYT/ESS Transistor (source)
  FX5-C16EYR/D-TS 16 points - - 16 points Relay Spring clamp terminal block *2
*2
  FX5-C16EYT/D 16 points - - 16 points Transistor (sink) Connector *2
*2
FX5-C16EYT/DSS Transistor (source)
  FX5-C32EYT/D 32 points 32 points Transistor (sink)
FX5-C32EYT/DSS Transistor (source)
  FX5-C32EYT/D-TS 32 points - - 32 points Transistor (sink) Spring clamp terminal block *2
*2
FX5-C32EYT/DSS-TS Transistor (source)

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.

page top

Input/output module

Model Total No.
of points
No. of input/output points
& Input/output type
Connection type Compatible CPU module
Input Output FX5U FX5UC FX5UJ
  FX5-16ER/ES 16 points 8 points 24 V DC (sink/source) 8 points Relay Screw terminal block *1
FX5-16ET/ES Transistor (sink)
FX5-16ET/ESS Transistor (source)
  FX5-C32ET/D 32 points 16 points 24 V DC (sink) 16 points Transistor (sink) Connector *2
*2
FX5-C32ET/DSS 24 V DC (sink/source) Transistor (source)
  FX5-C32ET/DS-TS 32 points 16 points 24 V DC (sink/source) 16 points Transistor (sink) Spring clamp terminal block *2
*2
FX5-C32ET/DSS-TS Transistor (source)

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.

page top

High-speed pulse input/output module

Model Total No.
of points
No. of input/output points
& Input/output type
Connection type Compatible CPU module
Input Output FX5U FX5UC FX5UJ
  FX5-16ET/ES-H 16 points 8 points 24 V DC (sink/source) 8 points Transistor (sink) Screw terminal block *1
*1 *2
×
FX5-16ET/ESS-H Transistor (source)

*1: Supported in version 1.030 or later.

Analog input devices (A/D conversion)

Model Input specifications Compatible CPU
module
Number of channels Item Input voltage Input current FX5U FX5UC FX5UJ
  FX5U CPU module 2 ch Input
range
0 to 10 V DC
(input resistance 115.7 kΩ)
- - - -
Resolution 2.5mV -
  FX5-4AD-ADP 4 ch Input
range
-10 to +10 V DC
(Input resistance 1 MΩ)
-20 to +20 mA DC
(Input resistance 250 Ω)

Max.
4 units

Max.
4 units

Max.
2 units
Input characteristics,
resolution
Analog
Input range
Resolution Analog
Input range
Resolution
10 to 10 V 625 μV 0 to 20 mA 1.25 μA
0 to 5 V 312.5 μV 4 to 20 mA 1.25 μA
1 to 5 V 312.5 μV -20 to 20 mA 2.5 μA
-10 to 10 V 1250 μV
  FX5-4AD 4 ch Input
range
-10 to +10 V DC
(Input resistance 400 kΩ or more)
-20 to +20 mA DC
(Input resistance 250 Ω)
*1
Input characteristics,
resolution
Analog
Input range
Resolution Analog
Input range
Resolution
0 to 10 V 312.5 μV 0 to 20 mA 625 nA
0 to 5 V 156.25 μV 4 to 20 mA 500 nA
1 to 5 V 125 μV -20 to +20 mA 625 nA
-10 to +10 V 312.5 μV
User range
setting
125 μV User range
setting
500 nA
  FX5-8AD 8 ch Input
range
-10 to 10 V DC
(Input resistance 1 MΩ)
-20 to +20 mA DC
(Input resistance 250 Ω)
*1
Input characteristics,
resolution
Analog
Input range
Resolution Analog
Input range
Resolution
0 to 10 V 312.5 μV 0 to 20 mA 625 nA
0 to 5 V 156.25 μV 4 to 20 mA 500 nA
1 to 5 V 125 μV -20 to +20 mA 625 nA
-10 to +10 V 312.5 μV
  FX3U-4AD 4 ch Input
range
-10 to +10 V DC
(input resistance 200 kΩ)
-20 to +20 mA DC,
4 to 20 mA
(Input resistance 250 Ω)
*2

Max.
Max. 6 to 8 modules
*3
*2

Max.
6 units
×
Resolution 0.32 mV
(20 V×1/64000)
1.25 μA
(40 mA×1/32000)

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.

page top

Analog output devices (D/A conversion)

Model Output specifications Compatible CPU
module
Number of channels Item Output voltage Output current FX5U FX5UC FX5UJ
PLC Splitter Melsec Iq-F Series Lineup Fx5u or Fx5UC, Fx5-Cnv-Bus or Fx5-Cnv-Busc
 
FX5U CPU module 1 ch Output
range
0 to 10 V DC
(External load resistance value 2 kΩ to 1 MΩ)
- - - -
Resolution 2.5 mV -
PLC Splitter Melsec Iq-F Series Lineup Fx5u or Fx5UC, Fx5-Cnv-Bus or Fx5-Cnv-Busc
 
FX5-4DA-ADP 4 ch Output
range
-10 to +10 V DC
(External load resistance value 1 kΩ to 1 MΩ)
0 to 20 mA DC
(External load resistance value 0 to 500 Ω)

Max.
4 units

Max.
4 units

Max.
2 units
Output characteristics,
resolution
Analog
Output range
Resolution Analog
Output range
Resolution
0 to 10 V 625 μV 0 to 20 mA 1.25 μA
0 to 5V 312.5 μV
1 to 5V 250 μV 4 to 20 mA 1 μA
-10 to 10 V 1250 μV
PLC Splitter Melsec Iq-F Series Lineup Fx5u or Fx5UC, Fx5-Cnv-Bus or Fx5-Cnv-Busc
 
FX5-4DA 4 ch Output
range
-10 to +10 V DC
(External load resistance value 1 kΩ to 1 MΩ)
0 to 20 mA DC
(External load resistance value 0 to 500 Ω)
*1
Output characteristics,
resolution
Analog
Output range
Resolution Analog
Output range
Resolution
0 to 10 V 312.5 μV 0 to 20 mA 625 nA
0 to 5 V 156.3 μV
1 to 5 V 125 μV 4 to 20 mA 500 nA
-10 to +10 V 312.5 μV
User range
setting
312.5 μV User range
setting
500 nA
PLC Splitter Melsec Iq-F Series Lineup Fx5u or Fx5UC, Fx5-Cnv-Bus or Fx5-Cnv-Busc
 
FX3U-4DA 4 ch Output
range
-10 to +10 V DC
(external load resistance value 1 kΩ to 1 MΩ)
0 to 20 mA DC,
4 to 20 mA DC
(External load resistance value 500 Ω or less)
*2

Max.
6 to 8 modules
*3
*2

Max.
6 units
×
Resolution 0.32 mV
(20 V × 1/64000)
0.63 μA
(20 mA × 1/32000)

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.

page top

Input device for temperature sensor

Model Number of channels Available sensor Input specifications Compatible CPU
module
Item Temperature input FX5U FX5UC FX5UJ
  FX5-4AD-PT-ADP 4 ch Usable resistance temperature detector
Pt100
Ni100
Input
range
[Typical example]
Pt100: -200 to +850˚C
Ni100: -60 to +250˚C

Max.
4 units

Max.
4 units

Max.
2 units
Resolution 0.1˚C
  FX5-4AD-TC-ADP 4 ch Thermocouple
K, J, T,
B, R, S
Input
range
[Typical example]
K type: -200.0 to 1200˚C
J type: -40.0 to 750˚C

Max.
4 units

Max.
4 units

Max.
2 units
Resolution 0.1 to 0.3˚C
(depending on the sensor used)
  FX5-8AD 8 ch Usable resistance temperature detector
Pt100
Ni100
Input
range
[Typical example]
Pt100: -200 to +850˚C
Ni100: -60 to +250˚C
*1
Resolution 0.1˚C
Thermocouple
K, J, T,
B, R, S
Input
range
[Typical example]
K type: -270.0 to 1200˚C
J type: -40.0 to 750˚C
Resolution 0.1 to 0.3˚C
(depending on the sensor used)
  FX5-4LC 4 ch Platinum resistance thermometer sensor
Pt100, JPt100, Pt1000
Input
range
[Typical example]
3-wire Pt100: -200 to 600˚C
3-wire JPt100: -200 to 500˚C
2-wire/3-wire Pt1000: -200.0 to 650.0˚C
*1
Resolution 0.1˚C or 1˚C
(depending on the sensor used)
Thermocouple
K, J, R, S,
E, T, B, N JIS C 1602-1995,
PLII, W5Re/W26Re, U, L
Input
range
[Typical example]
K type: -200.0 to 1300˚C
J type: -200.0 to 1200˚C
Resolution 0.1˚C or 1˚C
(depending on the sensor used)
Micro voltage input Input
range
0 to 10 mV DC
0 to 100 mV DC
Resolution 0.5 μV or 5.0 μV
(depending on the sensor used)
  FX3U-4LC 4 ch Platinum resistance thermometer sensor
Pt100, JPt100, Pt1000
Input
range
[Typical example]
3-wire Pt100: -200 to 600˚C
2-wire/3-wire Pt1000: -200.0 to 650.0˚C
*2

Max.
6 to 8
modules
*3
*2

Max.
6 units
×
Resolution 0.1˚C or 1˚C
(depending on the sensor used)
Thermocouple
K/J/R/S/E/T/B/
N/PLII/W5Re/
W26Re/U/L type
Input
range
[Typical example]
K type: -200.0 to 1300˚C
J type: -200.0 to 1200˚C
Resolution 0.1˚C or 1˚C
(depending on the sensor used)
Low voltage input Input
range
0 to 10 mV DC
0 to 100 mV DC
Resolution 0.5 μV or 5.0 μV
(depending on the sensor used)

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.
 

High speed counter

Model Number of channels Type Highest response
frequency
Hardware
comparison output function
2-phase counter
edge count function
Compatible CPU module
FX5U FX5UC FX5UJ
  FX3U-2HC 2 ch 1 phase
1 input
Max. 200 kHz - *

Up to
2 modules
*

Up to
2 modules
×
1 phase
2 input
Max. 200 kHz
2 phase
2 input
1 edge count: Max. 200 kHz
2 edge count: Max. 100 kHz
4 edge count: Max. 50 kHz

*: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

page top

High-speed pulse input/output module

Model Generic Specifications Function Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-16ET/ES-H Max. 2 ch 200 kHz High-speed counter function
- Normal mode
Pulse Width Measurement Function
Pulse Catch Function
General-purpose Input Functions
*1

Up to 4 modules
*1*2

Up to 4 modules
×
FX5-16ET/ESS-H

*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page top

FX5U/FX5UC/FX5UJ CPU module built-in input functions (Built-in high-speed counter function)

Model Generic Specifications Function
  FX5U CPU module Max. 8ch 200kHz
FX5U-32M: 6 ch 200kHz + 2 ch 10kHz
High-speed counter function
- Normal mode
- Pulse density measurement mode
- Rotation speed measurement mode
FX3-compatible high-speed counter function
Pulse Width Measurement Function
Pulse Catch Function
- Pulse Catch Function
- FX3-Compatible Pulse Catch Function
General-purpose Input Functions
  FX5UC CPU module Max. 8 ch 200kHz
FX5UC-32M: 6 ch 200kHz + 2 ch 10kHz
  FX5UJ CPU module Max. 4 ch 100kHz + 4 ch 10 Hz
 

Simple Motion Module (SSCNET III/H)

Model Number of control axes Main functions/Control Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-40SSC-S 4 axes Function
Linear interpolation
Circular interpolation
Continuous trajectory control
S-curve acceleration/deceleration
Control
Synchronous control
Cam control
Torque control

Up to
16 modules
*1

Up to
8 modules
*2

Up to
1 modules
  FX5-80SSC-S 8 axes Function
Linear interpolation
Circular interpolation
Continuous trajectory control
S-curve acceleration/deceleration
Control
Synchronous control
Cam control
Torque control

Up to
16 modules
*1

Up to
8 modules
*2

Up to
1 modules

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: FX5-40SSC-S and FX5-80SSC-S cannot be used together.

page top

High-speed pulse input/output module

Model Number of control axes Maximum frequency Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-16ET/ES-H 2 axes 200 kpps *1

Up to 4 modules
*1 *2

Up to 4 modules
×
FX5-16ET/ESS-H

*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page top

Positioning module

Model Number of control axes Maximum frequency Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-20PG-P 2 axes 200 kpps *1
  FX5-20PG-D 2 axes 5 Mpps *1
  FX3U-1PG 1 axis 200 kpps *2

Max.
6 to 8 modules
*3
*2

Max.
6 modules
×

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.

page top

FX5U/FX5UC/FX5UJ CPU module built-in output functions (Built-in positioning function)

Model Generic Specifications Function
  FX5U CPU module Max. 200 kHz 4 axes
*Supported by transistor output type CPU module
JOG operation (Supported by variable speed operation)
Machine home position return
Fast home position return control
1-speed positioning
2-speed positioning
Multi-speed operation
Interrupt stop
Interrupt and 1-speed positioning
Interrupt and 2-speed positioning
Variable speed operation
Simple linear interpolation (Start 2-Axis simultaneously)
Table operation
Absolute position detection system
  FX5UC CPU module
  FX5UJ CPU module Max. 200 kHz 3 axes
*Supported by transistor output type CPU module

CC-Link IE field network

Model Master station function Remote,
slave function
Distance Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-CCLIEF
CC-Link IE field network
(Intelligent device station)
× 100 m *1

Up to 1 module
*1 *2

Up to 1 module

Up to 1 module

*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page top

CC-Link

Model Master station function Remote,
slave function
Distance Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-CCL-MS
CC-Link system
master/intelligent
device module
1200 m *1
  FX3U-16CCL-M *2
CC-Link
(Master station)
× 1200 m *3

Up to
1 module
*3

Up to
1 module
×
  FX3U-64CCL
CC-Link
(Intelligent device station)
×

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*2: When CC-Link master and AnyWire Bitty master or AnyWireASLINK master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASLINK master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user's manuals.

*3: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

page top

Ethernet

Model Data
transmission speed
Maximum
segment length
Supported protocol No. of connections
  FX5U CPU module 100 / 10 Mbps 100 m
(The distance between hub and node)
CC-Link IE field network Basic
FTP Server
SNTP client
Web server (HTTP)
Simple CPU communication function
MELSOFT connection
SLMP (3E frame)
Socket communication
Predefined protocol support
MODBUS/TCP communication
Total of 8 connections*1*2
(Up to 8 external devices are accessible to one CPU module at a time.)
  FX5UC CPU module
  FX5UJ CPU module
  FX5-ENET
Ethernet module

CC-Link IE field network Basic
Socket communication

Total of 32 connections*3
(Up to 32 external devices are accessible to one FX5-ENET at a time.)
  FX5-ENET/IP
EtherNet/IP module

EtherNet/IP
Socket communication

Total of 32 connections
(Up to 32 external devices are accessible to one FX5-ENET/IP at a time.)

*1: The first device for MELSOFT connection is not included in the number of connections. (The second and the following devices are included.)

*2: The CC-Link IE field network Basic, FTP server, SNTP client, Web server and simple CPU communication function are not included in the number of connections.

*3: The CC-Link IE field network Basic are not included in the number of connections.

page top

EtherNet/IP

Model Data
transmission speed
Maximum
segment length
Supported protocol Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-ENET/IP
EtherNet/IP module
100 / 10 Mbps 100 m
(The distance between hub and node)

Class 1 communications
Class 3 communications
UCMM communications


Up to 1 module
*1

Up to 1 module

Up to 1 module

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page top

PROFIBUS-DP

Model Transmission protocol Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-DP-M
PROFIBUS-DP Master module
PROFIBUS-DP
Up to 1 module
*1

Up to 1 module

Up to 1 module

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page top

Sensor Solution

Model Transmission protocol Number of connected I/O points Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-ASL-M
AnyWireASLINK system master module
Dedicated protocol
(AnyWireASLINK)
448 points maximum *1*2*3
(input: maximum 256 points,
output: maximum 256 points)

Up to
1 module
*4

Up to
1 module

Up to
1 module
  FX3U-128BTY-M *5
AnyWire Bitty series
master
Dedicated protocol
(AnyWire Bitty)
Up to 128 points *6

Up to
1 module
*6

Up to
1 module
×
  FX3U-128ASL-M *5
AnyWireASLINK system master
Dedicated protocol
(AnyWireASLINK)

*1: The number of available remote I/O points per system varies depending on the number of I/O points of the extension devices.
*2: The maximum number of points that can be used differs depending on the version of the CPU module used.

*3: When connecting to the FX5UJ CPU module, the maximum is 216 points (input: maximum 192 points, output: maximum 192 points).

*4: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*5: When CC-Link master and AnyWire Bitty master or AnyWireASLINK master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASLINK master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user's manuals.

*6: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

page top

MODBUS communication

Model Communication interface Maximum transmission distance Generic Specifications Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-232-BD RS-232C 15 m Predefined protocol: RTU
No. of connectable slaves: 1

Up to
1 modules
×
Up to
1 modules
  FX5-232ADP
Up to
2 modules

Up to
2 modules

Up to
2 modules
  FX5U CPU module RS-485 50 m Predefined protocol: RTU
No. of connectable slaves: 32
- - -
  FX5UC CPU module - - -
  FX5-485-BD 50 m
Up to
1 module
×
Up to
1 module
  FX5-485ADP 1200 m
Up to
2 module

Up to
2 module

Up to
2 module
page top

Serial communication

Model Communication interface Maximum transmission distance Function type Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-232-BD RS-232C 15 m MELSOFT connection
MELSEC Communication protocol (1C/3C/4C frames)
Non-protocol communication
Predefined protocol support

Up to
1 module
×
Up to
1 module
  FX5-232ADP
Up to
2 module

Up to
2 module

Up to
2 module
  FX5U CPU module RS-485 50 m MELSOFT Connection
MELSEC Communication protocol (1C/3C/4C frames)
Non-protocol communication
Inverter communication
N:N network
Parallel link
Predefined protocol support
- - -
  FX5UC CPU module - - -
  FX5-485-BD 50 m
Up to
1 module
×
Up to
1 module
  FX5-485ADP 1200 m
Up to
2 module

Up to
2 module

Up to
2 module
  FX5-422-BD-GOT RS-422 As per GOT specifications GOT connection
Up to
1 module
-
Up to
1 module
 

Safety main module

Item Total No. of points Safety inputs Safety outputs Safety integrity level (SIL) Performance level (PL) Off delay time Built-in program Connection type Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-SF-MU4T5 8 points 4 points 4 points SIL3 (IEC 61508) PL e (DIN EN ISO 13849-1) 0 / 0.5 / 1 /1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 5 s 9 types Spring clamp terminal block *
×

*: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page top

Safety expansion module

Safety input expansion module

Item Total No. of points Safety inputs Safety outputs Safety integrity level (SIL) Performance level (PL) Off delay time Built-in program Connection type Compatible CPU module*3
FX5U FX5UC FX5UJ
  FX5-SF-8DI4 8 points 8 points 0 points SIL3 (IEC 61508) PL e (DIN EN ISO 13849-1) *1 *2
9 types
Spring clamp terminal block *4
×

*1: Set the off delay time in the safety main module.
*2: The built-in program can set the logical path connection method with the safety main module for INPUT A and INPUT B each.
*3: Safety main module is required to connect to the CPU modules.
*4: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
 

Extension power supply module

Model Specifications Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-1PSU-5V Power supply for FX5 extension module
Internal 5V DC: 1.2 A *1
Internal 24 V DC: 0.3 A *1
○ (AC power supply type)
Up to 2 modules
*3
×
Up to
1 module
  FX3U-1PSU-5V Power supply for FX3 extension module
Internal 5 V DC: 1 A *1
Internal 24 V DC: 0.3 A *1
*2
○ (AC power supply type)
Up to 2 modules
*3
× ×
  FX5-C1PS-5V Power supply for FX5 extension module
[Output current]
5 V DC: 1200 mA *1
24 V DC: 625 mA *1

*4
○ (DC power supply type)
Up to 2 modules


Up to
2 modules
×

*1: Maximum output current depends on the ambient temperature.
*2: When connecting to FX5U, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
*3: Max. of total two FX5-1PSU-5V and FX3U-1PSU-5V can be connected in one system.
*4: When connecting to FX5U, FX5-CNV-IF is required.

page top

Connector conversion module

Model Specifications Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-CNV-IF Connector conversion module used from FX5 (extension cable type)
to connect FX5 (extension connector type) extension modules.
Control power: not consumed

Up to
1 module
×
Up to
1 module
  FX5-CNV-IFC Connector conversion module used from FX5 (extension connector type)
to connect FX5 (extension cable type) extension modules.
Control power: not consumed
×
Up to
1 module
×
page top

Connector conversion adapter

Model Specifications Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-CNV-BC Connector conversion adapter
Up to
1 module

Up to
1 module

Up to
1 module
page top

Extension cable

Model Length Application Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-30EC 0.3m Extension cable for extension module
Up to
1 module

Up to
1 module

Up to
1 module
FX5-65EC 0.65m
page top

Bus conversion module

Model Specifications Compatible CPU module
FX5U FX5UC FX5UJ
  FX5-CNV-BUS Bus conversion FX5 (extension cable type) -> FX3 extension
Control power: 5 V DC 150 mA (supplied from PLC)

Up to
1 module
*1

Up to
1 module
×
  FX5-CNV-BUSC Bus conversion FX5 (extension connector type) -> FX3 extension
Control power: 5 V DC 150 mA (supplied from PLC)
*2

Up to
1 module

Up to
1 module
×

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to FX5UC.
*2: FX5-CNV-IF is necessary to connect to FX5U.

page top

Terminal modules

Terminal modules are used to convert connector-type I/O terminals into terminal blocks.
By using terminal blocks (built-in element type) dedicated to input or output, capturing of AC input signals and format conversion into the relay/transistor/triac output can be performed.

Model No. of input
points
No. of output
points
Function
  FX-16E-TB 16 input points or 16 output points Directly connected to the I/O terminal of PLC.
Using this unit instead of a terminal block or relaying a wiring of I/O device located remotely from PLC enables reducing of the man-hours of I/O wiring.
FX-16E-TB/UL
  FX-32E-TB 32 input points, 32 output points, or
16 input points and 16 output points
FX-32E-TB/UL
  FX-16EYR-TB - 16 points Relay output type
FX-16EYR-ES-TB/UL
FX-16EYS-TB Triac output type
FX-16EYS-ES-TB/UL
FX-16EYT-TB Transistor output type (sink)
FX-16EYT-ES-TB/UL
FX-16EYT-ESS-TB/UL Transistor output type (source)
page top

SD memory card

Model Specifications Compatible CPU module
Type Capacity Number of writes FX5U FX5UC FX5UJ
NZ1MEM-2GBSD SD memory card 2G bytes 60,000 times
Up to
1 module

Up to
1 module

Up to
1 module
NZ1MEM-4GBSD SDHC memory card 4G bytes 100,000 times
NZ1MEM-8GBSD 8G bytes
NZ1MEM-16GBSD 16G bytes
page top

Battery

Model Application Compatible CPU module
FX5U FX5UC FX5UJ
  FX3U-32BL The battery will be used when you desire to retain (latch) * the status of the device memory or clock data before a power failure.
At the time of delivery from a plant, the battery is not built in the CPU module.
Please make arrangements if required.

Up to
1 module

Up to
1 module
×

*: Setting of parameter is required for a power failure retention.

page top

Cable

Model Length Application
  FX-232CAB-1 3.0 m Use a communication cable to connect a PLC with a personal computer by RS-232C communication.
FX5-232ADP <-> Personal computer
FX5-232-BD * <-> Personal computer

*: FX5-232-BD can be connected to the FX5U/FX5UJ CPU module.

More Products