Your Position: Home > Product > Mitsubishi

Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D

Update: 2020/12/14      View:
  • Brand:    Mitsubishi
  • Type:    FX3GA-60MR
  • Price:    1900 RMB
  • Promotion:    1500 RMB ( 0 Customers Bought)
  • Order Online   Add to favorites
Introduction

Rich features and flexible system configuration in a compact size.

The MELSEC-F series PLC incorporates power supply, CPU, and I/Os into a single compact unit.
Meets the needs of a variety of user applications with options for I/O, analog, positioning, and open network expansion.
Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D

High functionality model (FX3U/FX3UC)

Faster, friendlier. Realize high expandability and high functionality.
Fom high speed control to network support and even logging is possible.
FX3 series flagship model FX3U and connector type FX3UC: 2 models are available.

Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 

Standard model (FX3G/FX3GC)

More advanced control for auotmation and networking.
Equipped with functions required for standard controls, and fit for various purposes.
Compact sized with the same performance, FX3GC is also available.

Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 

Basic model (FX3S)

Easy introduction to machine automation.
Simple functions and economical price in one package.
A basic micro PLC with expandability for analog and communication functions.

Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
FX series I/O extension devices are divided into "extension blocks" and "powered extension units".
"Powered extension units" have built-in power supply and also extend I/O at the same time.
"Extension blocks" adjust the I/O of the main unit or powered extension units in 8 point or 16 point units.
 

Extension units

Powered extension units are I/O extension devices with built-in power supply.
Like with the main unit, various I/O devices and special devices can be connected after a powered extension unit.

Model Total number
of points
Number of input/output points
Input/output type
Applicable FX PLC
Input Output FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
AC Power Type
Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 
FX2N-32ER 32 points 16 points 24 V DC
(sink)
16 points Relay × × ×
FX2N-32ER-ES/UL 24 V DC
(sink/
source)
FX2N-32ES 24 V DC
(sink)
Triac
FX2N-32ET 24 V DC
(sink)
Transistor
(sink)
FX2N-32ET-ESS/UL 24 V DC
(sink/
source)
Transistor
(source)
Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 
FX2N-48ER 48 points 24 points 24 V DC
(sink)
24 points Relay × × ×
FX2N-48ER-ES/UL DC24V
(sink/
source)
FX2N-48ET 24 V DC
(sink)
Transistor
(sink)
FX2N-48ET-ESS/UL 24 V DC
(sink/
source)
Transistor
(source)
  FX2N-48ER-UA1/UL 48 points 24 points 100 V AC 24 points Relay × × ×
DC Power Type
Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 
FX2N-48ER-D 48 points 24 points 24 V DC
(sink)
24 points Relay × × ×
FX2N-48ER-DS 24 V DC
(sink/
source)
FX2N-48ET-D 24 V DC
(sink)
Transistor
(sink)
FX2N-48ET-DSS 24 V DC
(sink/
source)
Transistor
(source)

Regarding connection cable
A connection cable (length: 55mm), used to connect to the the right side of the device in front of the powered extension unit, is included with the powered extension unit. To extend the distance of the connection, please use the optional "extension cable".

page top

Function expansion board

The expansion board is designed to add the input and output terminal whose points are small to FX3S or FX3G PLCs. The board can be built in the PLC.

Model Total
number
of
points
Number of input/output points
Input/output type
Applicable FX PLC
Input Output FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 
FX3G-4EX-BD 4
points
4
points
24 V DC
(sink/
source)
- - *1

Max.
1 unit
*2

Max.
1 unit
× × ×
Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 
FX3G-2EYT-BD 2
points
- - 2
points
Transistor
(sink/
source)
*1

Max.
1 unit
*2

Max.
1 unit
× × ×

*1: Supported by FX3S ver.1.10 and later.
*2: Supported by FX3G ver.2.20 and later.

page top

Extension blocks

Extension block is an I/O extension device that receives power from the main unit or powered extension unit.
It can be connected in 8 point or 16 point units. The connectable number of points is determined by each main unit or powered extension unit

Model Total number
of points
Number of input/output points
Input/output type
Applicable FX PLC
Input Output FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
Input/output extension blocks
Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 
FX2N-8ER 8 points 4 points
(8 devices
are occupied.)
24 V DC
(sink)
4 points
(8 devices
are occupied.)
Relay × *1
*2
*1
*2
FX2N-8ER-ES/UL DC24V
(sink/
source)
FX2N-8EX 8 points 24 V DC
(sink)
- -
FX2N-8EX-ES/UL DC24V
(sink/
source)
FX2N-8EX-UA1/UL 100 V AC
Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 
FX2N-16EX 16 points 16 points 24 V DC
(sink)
× *1
*2
*1
*2
FX2N-16EX-ES/UL 24 V DC
(sink/
source)
FX2N-16EX-C
Connector input
24 V DC
(sink)
FX2N-16EXL-C
Connector input
5 V DC
Output extension blocks
Mitsubishi PLC Fx3u-80mt-Ds Fx3u-128mt-Es-a Fx3u-64mr-Es-a Fx2-128mr Fx2-64mr-D
 
FX2N-8EYR 8 points - - 8 points Relay × *1
*2
*1
*2
FX2N-8EYR-ES/UL
FX2N-8EYR-S-ES/UL Relay
(8 points/common)
FX2N-8EYT Transistor
(sink)
FX2N-8EYT-H
FX2N-8EYT-ESS/UL Transistor
(source)
  FX2N-16EYR 16 points 16 points Relay × *1
*2
*1
*2
FX2N-16EYR-ES/UL
FX2N-16EYS Triac
FX2N-16EYT Transistor
(sink)
FX2N-16EYT-ESS/UL Transistor
(source)
FX2N-16EYT-C
Connector output
Transistor
(sink)

*1 :For connection to FX3GC or FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2 :Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit.

Regarding connection cable
A connection cable, used to connect to the right side of the device in front of the extension block, is included with the extension block.
To extend the distance of the connection, please use the optional "extension cable (FX0N-30EC/FX0N-65EC)" and "connector conversion adapter (FX2N-CNV-BD)".

page top

Extension block for connector type main unit (FX3GC, FX3UC)

These I/O extension devices can be directly connected to FX1NC, FX3GC, FX2NC, FX3UC PLCs.
They can be compactly extended because connection cables are not needed.

Model Total number
of points
Number of input/output points
Input/output type
Applicable FX PLC
Input Output FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
Input extension blocks
  FX2NC-16EX-T
Terminal block input
16 points 16 points 24 V DC
(sink)
- - × × × *
*
FX2NC-16EX-T-DS
Terminal block input
DC24V
(sink/
source)
  FX2NC-16EX DC24V
(sink)
FX2NC-16EX-DS DC24V
(sink/
source)
FX2NC-16EX-D/UL DC24V
(sink)
  FX2NC-32EX 32 points 32 points 24 V DC
(sink)
FX2NC-32EX-DS DC24V
(sink/
source)
FX2NC-32EX-D/UL DC24V
(sink)
Output extension blocks
  FX2NC-16EYR-T
Terminal block Output
16 points - - 16 points Relay × × × *
*
FX2NC-16EYR-T-DS
Terminal block output
  FX2NC-16EYT Transistor
(sink)
FX2NC-16EYT-DSS Transistor
(source)
FX2NC-16EYT-D/UL Transistor
(sink)
  FX2NC-32EYT 32 points 32 points Transistor
(sink)
FX2NC-32EYT-DSS Transistor
(source)
FX2NC-32EYT-D/UL Transistor
(sink)
Input/output extension blocks
  FX2NC-64ET 64 points 32 points 24 V DC
(sink)
32 points Transistor
(sink)
× × × *
*

*: Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit
By using analog input blocks and output blocks, analog quanties (voltage, current, etc.) can be input or output.
Analog control, which is indispensable in FA control, can be easily realized with PLC.
 

Analog expansion board (A/D conversion, D/A conversion)

Model
(Number of channels)
Input specifications Applicable FX PLC
Item Input voltage Input current FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX3G-2AD-BD
(Input 2 ch)
Input
range
0 to 10 V DC
(Input resistance 198.7 kΩ)
4 to 20 mA DC
(Input resistance 250 Ω)
*3

Max.
1 unit
*1*2

Max.
2 units
× × ×
Resolution 2.5 mV
(10 V/4000)
8 μA
{(20 - 4 mA)/2000}
FX3G-1DA-BD
(Output 1 ch)
Output
range
0 to 10 V DC
(External load resistance value
2 kΩ to 1 MΩ)
4 to 20 mA DC
(External load resistance value
500 Ω or less)
*3

Max.
1 unit
*1*2

Max.
2 units
× × ×
Resolution 2.5 mV
(10 V/4000)
8 μA
{(20 - 4 mA)/2000}

*1: Supported by FX3G ver. 1.10 and later.
*2: FX3G 14pt, 24pt models: 1 board. 40pt, 60pt models: 2 boards.
*3: Function expansion board and FX3S-CNV-ADP cannot be used together.

page top

Mixed Analog Input/Output (A/D conversion, D/A conversion)

Model
(Number of channels)
Input/output specifications Applicable FX PLC
Item Input/output voltage Input/output current FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX3U-3A-ADP
(Input 2 ch)
(Output 1ch)
Input
range
0 to 10 V DC
(Input resistance
198.7 kΩ)
4 to 20 mA DC
(Input resistance 250 Ω)
*7

Max.
1 unit
*1*6

Max.
2 units
*2

Max.
4 units

Max.
2 units
*3

Max.
4 units
Output
range
0 to 10 V DC
(External load resistance value
5 kΩ to 1 MΩ)
4 to 20 mA DC
(External load resistance value
500 Ω or less)
Resolution [Input voltage]
2.5 mV (10 V/4000)
[Output voltage]
2.5 mV (10 V/4000)
[Input current]
5 μA (16 mA/3200)
[Onput current]
4 μA (16 mA/4000)
FX2N-5A
(Input 4 ch)
(Output 1ch)
Input
range
-100 to 100 mV DC
-10 to 10 V DC
(Input resistance 200 kΩ)
-20 to 20 mA DC
4 to 20 mA DC
(Input resistance 250 Ω)
× ×
Max.
8 units
× *4*5

Max.
8 units
Output
range
-10 to 10 V DC
(External load resistance value
2 kΩ to 1 MΩ)
0 to 20 mA DC,
4 to 20 mA DC
(External load resistance value
500 Ω or less)
Resolution 50 μV
(at ±100 mV)
312.5 μV
(at ±10 V)
1.25 μA,10 μA
((depending on
mode used))

*1: Supported by FX3G ver.1.20 and later. For connection to FX3G, FX3G-CNV-ADP is required.
*2: Supported by FX3U ver.2.61 and later. For connection to FX3U, function expansion board is required.
*3: Supported by FX3UC ver.2.61 and later. When connecting to FX3UC-32MT-LT(-2), function expansion board is required.
*4: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*5: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.
*6: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.
*7: For connection to FX3S, FX3S-CNV-ADP is required.

page top

Analog Input (A/D conversion)

Model
(Number of channels)
Input specifications Applicable FX PLC
Item Input voltage Input current FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX3S-30MR/ES-2AD
FX3S-30MT/ES-2AD
FX3S-30MT/ESS-2AD
(Input 2ch)
Input
range
0 to 10 V DC
(Input resistance 115.7 kΩ)
- - - - - -
Resolution 10 mV
(10 V/1000)
-
FX2N-2AD
(Input 2 ch)
Input
range
0 to 10 V DC,
0 to 5 V DC
(Input resistance 200 kΩ)
The input characteristic is the same for each channel.
4 to 20 mA DC
(Input resistance 250 Ω)
The input characteristic is the same for each channel.
× ×
Max.
8 units
× *1*2

Max.
8 units
Resolution 2.5 mV
(10 V × 1/4000)
1.25 mV
(5 V × 1/4000)
4 μA
((20 - 4 mA) × 1/4000)
FX3U-4AD
(Input 4ch)
Input
range
-10 to 10 V DC
(Input resistance 200 kΩ)
-20 to 20 mA DC,
4 to 20 mA
(Input resistance 250 Ω)
× ×
Max.
8 units
× *1*2

Max.
8 units
Resolution 0.32 mV
(20 V × 1/64000)
1.25 μA
(40 mA × 1/32000)
FX3U-4AD-ADP
(Input 4ch)
Input
range
0 to 10 V DC
(Input resistance 194 kΩ)
4 to 20 mA DC
(Input resistance 250 Ω)
*8

Max.
1 unit
*4*3

Max.
2 units
*5

Max.
4 units

Max.
2 units
*5*6

Max.
4 units
Resolution 2.5 mV
(10 V/4000)
10 μA
(16 mA/1600)
FX3UC-4AD
(Input 4ch)
Input
range
-10 to 10 V DC
(Input resistance 200 kΩ)
4 to 20 mA DC,
-20 to 20 mA DC
(Input resistance 250 Ω)
× × × × *7*2

Max.
8 units
Resolution 0.32 mV
(20 V × 1/64000)
2.50 mV
(20 V × 1/8000)
1.25 μA
(40 mA × 1/32000)
5.0 μA
(40 mA × 1/8000)
FX2N-8AD
(Input 8 ch)
Input
range
-10 to 10 V DC
(Input resistance 200 kΩ)
4 to 20 mA DC
-20 to 20 mA DC
(Input resistance 250 Ω)
× ×
Max.
8 units
× *1*2

Max.
8 units
Resolution 0.63 mV
(20 V × 1/32000)
2.50 mV
(20 V × 1/8000)
2.5 μA
(40 mA × 1/16000)
2 μA
(16 mA × 1/8000)
5.0 μA
(40 mA × 1/8000)
4 μA
(16 mA × 1/4000)

*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.
*3: FX3G 14pt, 24pt models: 1 board. 40pt, 60pt models: 2 boards.
*4: When connecting to FX3G, FX3G-CNV-ADP is required.
*5: When connecting to FX3U, function expansion board is required.
*6: FX3UC-32MT-LT supported from version 1.20 or later.
*7: FX3UC-32MT-LT supported from version 1.30 or later.
*8: When connecting to FX3S, FX3S-CNV-ADP is required.

page top

Analog Output (D/A conversion)

Model
(Number of channels)
Output specifications Applicable FX PLC
Item Output voltage Output current FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX2N-2DA
(Output 2 ch)
Output
range
0 to 10 V DC,
0 to 5 V DC
(External load resistance value
2 kΩ to 1 MΩ)
4 to 20 mA DC
(External load resistance value
400 Ω or less)
× ×
Max.
8 units
× *1*2

Max.
8 units
Resolution 2.5 mV
(10 V × 1/4000)
1.25 mV
(5 V × 1/4000)
4 μA
((20 - 4) mA × 1/4000)
FX3U-4DA
(Output 4 ch)
Output
range
-10 to 10 V DC
(External load resistance value
1 kΩ to 1 MΩ)
0 to 20 mA DC
4 to 20 mA DC
(External load resistance value
500 Ωor less)
× ×
Max.
8 units
× *1*2

Max.
8 units
Resolution 0.32 mV
(20 V × 1/64000)
0.63 μA
(20 mA × 1/32000)
FX3U-4DA-ADP
(Output 4 ch)
Output
range
0 to 10 V DC
(External load resistance value
5 kΩ to 1 MΩ)
4 to 20 mA DC
(External load resistance value
500 Ω or less)
*7

Max.
1 unit
*3*4

Max.
2 units
*5

Max.
4 units

Max.
2 units
*5*6

Max.
4 units
Resolution 2.5 mV
(10 V/4000)
4 μA
(16 mA/4000)

*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.
*3: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.
*4: When connecting to FX3G, FX3G-CNV-ADP is required.
*5: When connecting to FX3U, FX3UC-32MT-LT(-2), function expansion board is required.
*6: FX3UC-32MT-LT supported from version 1.20 or later.
*7: When connecting to FX3S, FX3S-CNV-ADP is required.
Using high speed counters, high speed signals from encoder ans sensors can be counted.
Because FX PLC has built-in high performance high speed counters, high speed control is possible with a simple program. A high speed counter block with hardware comparator is also available.
 

High speed counter block/adapter

Model
(Number of channels)
Type Highest response
frequency
Hardware comparison
output function
2-phase counter
edge count function
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX2N-1HC
(1ch)
1-phase
1-count
Max. 50 kHz - × ×
Max.
8 units
× *2*3

Max.
8 units
1-phase
2-count
Max. 50 kHz
2-phase
2-count
1 edge count:
Max. 50 kHz
2 edge count:
Max. 25 kHz
4 edge count:
Max. 12.5 kHz
FX3U-2HC
(2ch)
1-phase
1-count
Max. 200 kHz - × ×
Max.
8 units
× *2

Max.
4 units
1-phase
2-count
Max. 200 kHz
2-phase
2-count
1 edge count:
Max. 200 kHz
2 edge count:
Max. 100 kHz
4 edge count:
Max. 50 kHz
FX2NC-1HC
(1ch)
1-phase
1-count
Max. 50 kHz - × × × × *3

Max.
8 units
1-phase
2-count
Max. 50 kHz
2-phase
2-count
1 edge count:
Max. 50 kHz
2 edge count:
Max. 25 kHz
4 edge count:
Max. 12.5 kHz
FX3U-4HSX-ADP
(4ch)
1-phase
1-count
Max. 200 kHz × × × *1

Max.
2 units
× ×
1-phase
2-count
Max. 200 kHz
2-phase
2-count
1 edge count:
Max. 100 kHz
4 edge count:
Max. 100 kHz

*1: When used together with analog or communication adapters, function expansion board is required.
*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.

page top

Built-in high speed counter function (high speed input adapter function)

FX3S Series PLC

Type Counter No.
Highest
response
frequency*
Max. response
frequency when
high speed processing
instruction is used*
Supported high speed processing instructions High
speed
counter
move
2 phase
counter
multi-
count
function
FX3U-4HSX-ADP
max. response
frequency
(FX3U only)
When
high speed
comparison
SET/RESET
is used
When
high speed
band
comparison
HSZ
is used
High
speed
comparison
SET
High
speed
comparison
RESET
High
speed
band
comparison
Counter
interrupt
High
speed
table
comparison
1-
phase
1-
count
C235,
C236,
C241
Max. 2pts:
Max. 60 kHz
overall frequency
60 kHz
× × × - ×
C237 to C240,
C242 to C245
Max. 4pts:
Max. 10 kHz
1-
phase
2-
count
C246
Max. 1pt:
Max. 60 kHz
C247,
C248,
C248(OP)
C249,
C250
Max. 2pts:
Max. 10 kHz
2-
phase
2-
count
C251
Max. 1pt:
Max. 30 kHz
×
C252,
C253,
C253(OP)
C254,
C255
Max. 2pts:
Max. 5 kHz

*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.

FX3G, FX3GC Series PLC

Type Counter No.
Highest
response
frequency*
Max. response
frequency when
high speed processing
instruction is used*
Supported high speed processing instructions High
speed
counter
move
2 phase
counter
multi-
count
function
FX3U-4HSX-ADP
max. response
frequency
(FX3U only)
When
high speed
comparison
SET/RESET
is used
When
high speed
band
comparison
HSZ
is used
High
speed
comparison
SET
High
speed
comparison
RESET
High
speed
band
comparison
Counter
interrupt
High
speed
table
comparison
1-
phase
1-
count
C235,
C236,
C238,
C239,
C241
Max. 4pts:
Max. 60 kHz
overall
frequency
60 kHz
× × × - ×
C237,
C240,
C242 to C245
Max. 2pts:
Max. 10 kHz
1-
phase
2-
count
C246,
C248(OP)
Max. 2pts:
Max. 60 kHz
C247 to C250
Max. 2pts:
Max. 10 kHz
2-
phase
2-
count
C251,
C253(OP)
Max. 2pts:
Max. 30 kHz
×
C252 to C255,
C254(OP)
Max. 2pts:
Max. 5 kHz

*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.

FX3U, FX3UC Series PLC

Type Counter No.
Highest
response
frequency*
Max. response
frequency when
high speed processing
instruction is used*
Supported high speed processing instructions High
speed
counter
move
2 phase
counter
multi-
count
function
FX3U-4HSX-ADP
max. response
frequency
(FX3U only)
When
high speed
comparison
SET/RESET
is used
When
high speed
band
comparison
HSZ
is used
High
speed
comparison
SET
High
speed
comparison
RESET
High
speed
band
comparison
Counter
interrupt
High
speed
table
comparison
1-
phase
1-
count
C235 to C240
Max. 6pts:
Max. 100 kHz
40 kHz 40-
(Number
of times of
use of instruction)
- 200kHz
C244(OP),
C245(OP)
Max. 2pts:
Max. 10 kHz
10 kHz 200 kHz
C241 to C245
Max. 3pts:
Max. 40 kHz
40 kHz -
1-
phase
2-
count
C246,
C248(OP)
Max. 2pts:
Max. 100 kHz
40 kHz 200 kHz
C247 to C250
Max. 2pts:
Max. 40 kHz
40 kHz -
2-
phase
2-
count
C251,
C253
Max. 2pts:
Max. 50 kHz
(1 edge count, 4 edge count)
1 edge count 40 kHz 100 kHz
4 edge count 10 kHz (40-
Number
of times of
use of
instruction)÷4
C252,
C253(OP),
C254,
C255
Max. 2pts:
Max. 40 kHz
1 edge count 40 kHz 40-
(Number
of times of use of instruction)
-
4 edge count 10 kHz (40-
Number
of times of
use of
instruction)÷4

*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.

Variety of functions

Built-in high speed counter numbers and allocation

Maximum frequency that the PLC can process

High speed comparison results can be obtained by a simple program and no calculation delay

FX3U, FX3U PLC counter mod
The FX series offers low cost PLCs with built-in positioning instructions and pulse output blocks that can perform wide-ranging positioning control.
Additionally, dedicated positioning modules for complex control and multi-axis, interpolation control are also available
 

High-speed output special adapter

Model Number of
controlled axis
Maximum
frequency
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3U-2HSY-ADP Independent two axes 200kHz × × *

Max.
2 units
× ×

*: When used together with analog or communication adapters, function expansion board is required

page top

Pulse output block

Model Number of
controlled axis
Maximum
frequency
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3U-1PG Independent one axis 200kHz × × *3

Max.
8 units
× *1*3

Max.
6 units
  FX2N-10PG Independent one axis 1MHz(1 Hz to 1 MHz
differential line driver output)
× ×
Max.
8 units
× *1*2

Max.
8 units

*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
*3: FX3U, FX3UC supported from version 2.20 or later.

page top

SSCNET

Model Number of
controlled axis
Maximum
frequency
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3U-20SSC-H Two axes
(Independent/Simultaneous)
- × ×
Max.
8 units
× *1*2

Max.
8 units

*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.

page top

Positioning dedicated unit

Model Number of
controlled axis
Maximum
requency
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX2N-10GM Independent one axis 200kHz × ×
Max.
8 units
× *1*2

Max.
8 units
  FX2N-20GM Two axes
(Independent/Simultaneous)
200kHz

*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.

page top

For FX2N-10GM/FX2N-20GM positioning teaching panel

Model Product
E-20TP-SET0
(with E-20TP-CAB0)
FX2N-10GM, FX2N-20GM
E-20TP-E-SET0
(with E-20TP-CAB0)
page top

Angle control unit

Model Number of
controlled axis
Maximum
frequency
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX2N-1RM-SET*1 One axis 720 divisions/rotation (0.5 degree)
or 360 divisions/rotation (1 degree)
× ×
Max.
3 units
× *2*3

Max.
3 units
FX2N-1RM-E-SET*1

*1: FX2N-1RM-SET is a Japanese domestic only product. For use overseas, please select FX2N-1RM-E-SET, which supports overseas standards.
*2: Extension cable cannot be used.
*3: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.

page top

PLC built-in pulse output functions and positioning functions

Items FX3S FX3G,FX3GC FX3U,FX3UC
Number of axis Two axes [FX3G]
Two axes (14/24 points)
Three axes (40/60 points)
[FX3GC]
Two axes
Three axes
Number of controlled axis Independent two axes [FX3G]
Independent two axes (14/24 points)
Independent three axes (40/60 points)
[FX3GC]
Independent two axes
Independent three axes
Maximum frequency 100 kHz 100 kHz 100 kHz
Programming languages Sequence programs Sequence programs Sequence programs
Compatible main unit Transistor
output type
main unit
Transistor
output type
main unit
Transistor
output type
main unit
Pulse
output instruction
Pulse Y Output
(PLSY)
Acceleration/Deceleration Setup
Pulse Y Output
(PLSR)
Pulse output type Pulse train
(Direction is controlled
by PLC program)
Pulse train
(Direction is controlled
by PLC program)
Pulse train
(Direction is controlled
by PLC program)
Positioning
instruction
Absolute Current Value Read
([D]ABS)
Dog Search
Zero Return
(DSZR)
Zero Return
(ZRN)
○*1 ○*1 ○*1
Variable Speed Pulse Output
(PLSV)
Drive to Increment
(DRVI)
Drive to Absolute
(DRVA)
Interrupt Positioning
(DVIT)
× ×
Batch Data Positioning Mode
([D]TBL)
× ○*2
Pulse output type Pulse train + direction Pulse train + direction Pulse train + direction
 

Details

Details

Details

*1: No DOG search function Decelerate when near point DOG turns ON, and stop when near point DOG turns OFF (Different from zero return operation with zero signal count)
*2: FX3UC-32MT-LT supported from version 2.20 or later.

page top

Optional parts and spare parts

Servo motor connection cable

Model Length Description
  E-GMH-200CAB 2 m [MR-H series servo amplifer connection cable]
Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.
I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block.
  E-GMJ-200CAB 2 m [MR-J series servo amplifer connection cable]
Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.
I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block.
  E-GMJ2-200CAB1A 2 m [MR-J2, MR-J2-Super series servo amplifer connection cable]
Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.
  E-GMC-200CAB 2 m [MR-C series servo amplifer connection cable]
Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.
I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block.
  E-GM-200CAB 2 m [General purpose connection cable]
Has connector on both sides.
Can connect to general purpose drive unit via Mitsubishi terminal block.

Connector for self-manufactured I/O cable (an electric wire or a crimp tool is not enclosed.)

Model Description
  FX2C-I/O-CON [Flat Cable Connector]
AWG28 (0.1 mm2): A set of 10 pcs

Crimp connector: FRC2-A020-3OS 1.27-pitch 20 cores

Crimp tool: Separately arrange the tool manufactured by DDK Ltd.
357J-4674D Main Unit
357J-4664N Attachment
  FX2C-I/O-CON-S [Connector for bared wire]
AWG22 (0.3 mm2): 5 sets

Housing: HU-200S2-001
Crimp contact: HU-411S

Crimp tool: A product manufactured by DDK Ltd. is separately required.
357J-5538
FX2C-I/O-CON-SA [Connector for bared wire]
AWG20 (0.5mm2): 5 sets

Housing: HU-200S2-001
Crimp contact: HU-411SA
Crimp tool: A product manufactured by DDK Ltd. is separately required.
357J-13963

Extension connection cable

Model Length Description
  FX2N-GM-65EC 65 cm [Connection extension cable between PLC and FX2N-10GM/FX2N-20GM]
One cable cable can be used in a system.
Standard connection cable (55mm) is included with FX2N-10GM/FX2N-20GM.
F2-RS-5CAB 5 m [Resolver extension cable for FX2N-1RM]
Resolver can be extended up to 100m extension by linking multiple cables.

Connection cable for peripheral devices

Model Length Description
  (1) E-20TP-CAB0 3 m [E-20TP connection cable]
FX2N-10GM/FX2N-20GM (MINI DIN 8-pin) ⇔ E-20TP (MINI DIN 8-pin)
Cable length is different between (1) and (2).
(1) E-20TP-CAB0 (3 m) is included with E-20TP-SET0.
(2) FX-20P-CAB0 1.5 m

Spare parts

Model Length Description
FX2N-GM-5EC 55 mm [Connection cable between PLC and FX2N-10GM/20GM]
One cable is included with FX2N-10GM/20GM.

CC-Link

Model Master station
function
Remote/slave
function
Distance Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3U-16CCL-M*1
CC-Link
master block
(Master station)
× 1,200 m maximum ×
Max.
1 unit
*4

Max.
1 unit
*2

Max.
1 unit
*2
*3

Max.
1 unit
  FX2N-32CCL
CC-Link
Interface block
(Remote device station)
× 1,200 m maximum × *2
*2
  FX3U-64CCL
CC-Link
Interface block
(Intelligent
device station)
× 1,200 m maximum ×
Max.
1 unit

Max.
1 unit
*2

Max.
1 unit
*2
*3

Max.
1 unit

*1: The FX3U-16CCL-M, FX2N-16CCL-M cannot be used at the same time with the FX2N-32ASI-M.
The FX3U-16CCL-M cannot be used at the same time with the FX2N-16CCL-M.
FX3U-16CCL-M and FX2N-16CCL-M cannot be used together.
[Remote I/O station]
Maximum 8 stations can be connected (1 station occupies 32 I/O points of the PLC)
[Total of remote device stations + intelligent device stations]
Maximum 8 stations can be connected (However, the total number of RX/RY points is 256 or less)

*2: When connecting to FX3GC,FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3UC supported from version 2.20 or later.
*4: FX3U supported from version 2.20 or later.

page top

CC-Link/LT

Model Master station
function
Remote/slave
function
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX2N-64CL-M
CC-Link/LT
master block
× ×
Max.
8 units

Max.
8 units
*1

Max.
5 units
*1

Max.
5 units
  FX3UC-32MT-LT
Built-in CC-Link/LT
master
× - - - - -
  FX3UC-32MT-LT-2
Built-in CC-Link/LT
master
× - - - - -

*1: When connecting to FX3GC,FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.

page top

CC-Link/LT: Power AdapterDedicated Power Supply

Model Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  CL1PAD1
Power Adapter
×
CL1PSU-2A
Dedicated Power Supply
×
page top

Ethernet

Model Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3U-ENET-L × × *1

Max.
1 unit
× *1
*2

Max.
1 unit
  FX3U-ENET-ADP *7
*8

Max.
1 unit
*3
*5

Max.
1 unit
*4
*6

Max.
1 unit
*3

Max.
1 unit
*4
*6

Max.
1 unit

*1: FX3U,FX3UC supported from version 2.21 or later.
*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3G, FX3GC supported from version 2.20 or later.
*4: FX3U, FX3UC supported from version 3.10 or later.
*5: When connecting to FX3G, FX3G-CNV-ADP is required.
*6: When connecting to FX3U or FX3UC-32MT-LT(-2), a function expansion board is required.
*7: When connecting to FX3S, FX3S-CNV-ADP is required.
*8: When connecting to FX3S, supported by FX3U-ENET-ADP Ver.1.20 or later.

page top

MODBUS

Model Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3U-232ADP-MB
Special adapter for
RS-232C communication
*7

Max.
1 unit
*1
*2
*3

Max.
2 units
*4
*5

Max.
2 units
*6

Max.
2 units
*4
*5

Max.
2 units
  FX3U-485ADP-MB
Special adapter for
RS-485 communication
*7

Max.
1 unit
*1
*2
*3

Max.
2 units
*4
*5

Max.
2 units
*6

Max.
2 units
*4
*5

Max.
2 units

*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.
*2: When connecting to FX3G, FX3G-CNV-ADP is required.
*3: FX3G supported from version 1.30 or later.
*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.
*5: FX3U, FX3UC supported from version 2.40 or later.
*6: FX3GC supported from version 1.40 or later.
*7: When connecting to FX3S, FX3S-CNV-ADP is required.

page top

PROFIBUS

Model Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3U-64DP-M
PROFIBUS-DP
Master block
× × *1
× *1
*2
*3
  FX3U-32DP
PROFIBUS-DP
Interface block
× *4
*1
*5
*6
*1
*2
*3

*1: FX3U, FX3UC supported from version 2.21 or later.
*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3UC-32MT-LT(-2) is not supported.
*4: FX3G supported from version 1.00 or later.
*5: When connecting to FX3GC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*6: FX3GC supported from version 1.40 or later.

page top

Sensor Solution

Model Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3U-128BTY-M
AnyWire Bitty series
master block
× *1

Max.
1 unit
*3

Max.
1 unit
*2
*4

Max.
1 unit
*3
*4

Max.
1 unit
  FX3U-128ASL-M
AnyWireASLINK system
special adapter
× *1

Max.
1 unit
*3

Max.
1 unit
*2
*4

Max.
1 unit
*3
*4

Max.
1 unit

*1: FX3G supported from version 1.00 or later.
*2: FX3GC supported from version 1.40 or later.
*3: FX3U, FX3UC supported from version 2.20 or later.
*4: When connecting to FX3GC, FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.

page top

RS-232C communication

Model Communication Function Applicable FX PLC
N:N network Parallel Link Computer Link Non-Protocol Communication Peripheral device communication FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3G-232-BD
Function expansion
board for RS-232C
communication
× × *10

Max.
1 unit
*1

Max.
2 units
× × ×
  FX3U-232-BD
Function expansion
board for RS-232C
communication
× ×
Max.
1 unit
× *2

Max.
1 unit
  FX3U-232ADP-MB
Specific adapter
for RS-232C
communication
× × *11

Max.
1 unit
*1
*3
*7

Max.
2 units
*4
*8

Max.
2 units
*9

Max.
2 units
*4
*8

Max.
2 units
  FX2N-232IF
Special block
for RS-232C
communication
× × × × × ×
Max.
8 units
× *5
*6

Max.
8 units

*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.
*2: Can only be connected to FX3UC-32MT-LT(-2).
*3: When connecting to FX3G, FX3G-CNV-ADP is required.
*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.
*5: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*6: For FX3UC-32MT-LT(-2), 7 units. For FX3UC-**MT/D, FX3UC-**MT/DSS, and FX3UC-16MR/D(S)-T, 8 units.
*7: FX3GC supported from version 1.30 or later.
*8: FX3U, FX3UC supported from version 2.40 or later.
*9: FX3GC supported from version 1.40 or later.
*10: Function expansion board and FX3S-CNV-ADP cannot be used together.
*11: When connecting to FX3S, FX3S-CNV-ADP is required.

page top

RS-485 communication

Model Communication Function Applicable FX PLC
N:N network Parallel Link Computer Link Non-Protocol Communication Peripheral device communication FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3G-485-BD
Function expansion
board for RS-485
communication
× *8

Max.
1 unit
*1

Max.
2 units
× × ×
  FX3G-485-BD-RJ
Function expansion board
for RS-485 communication
(RJ-45 connector type)
*8

Max.
1 unit
*1

Max.
2 unit
× × ×
  FX3U-485-BD
Function expansion
board for RS-485
communication
× ×
Max.
1 unit
× *2

Max.
1 unit
  FX3U-485ADP-MB
Specific adapter
for RS-485
communication
× *9

Max.
1 unit
*1
*3
*5

Max.
2 units
*4
*6

Max.
2 units
*7

Max.
2 units
*4
*6

Max.
2 units
  FX-485PC-IF-SET

 

RS-232C/RS-485
converter interface
× × × ×

*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.
*2: Can only be connected to FX3UC-32MT-LT(-2).
*3: When connecting to FX3G, FX3G-CNV-ADP is required.
*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.
*5: FX3G supported from version 1.30 or later.
*6: FX3U, FX3UC supported from version 2.40 or later.
*7: FX3GC supported from version 1.40 or later.
*8: Function expansion board and FX3S-CNV-ADP cannot be used together.
*9: When connecting to FX3S, FX3S-CNV-ADP is required.

page top

RS-422 communication

Model Communication Function Applicable FX PLC
N:N network Parallel Link Computer Link Non-Protocol Communication Peripheral device communication FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3G-422-BD
Function expansion
board for RS-422
communication
× × × × *3

Max.
1 unit
*1

Max.
2 units
× × ×
  FX3U-422-BD
Function expansion
board for RS-422
communication
× ×
Max.
1 unit
× *2

Max.
1 unit

*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.
*2: Can only be connected to FX3UC-32MT-LT(-2).
*3: Function expansion board and FX3S-CNV-ADP cannot be used together.

page top

USB communication

Model Communication Function Applicable FX PLC
N:N network Parallel Link Computer Link Non-Protocol Communication Peripheral device communication FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
  FX3U-USB-BD
Function expansion
board for USB
communication
× × × × × ×
Max.
1 unit
× *

Max.
1 unit

*: Can only be connected to FX3UC-32MT-LT(-2).

page top

Communication function

CC-Link

CC-Link is an open network enabling connection of various FA equipment.
We prepare a master unit setting FX PLC as master blocks of CC-Link, as well as an interface setting them as remote device stations of CC-Link.

Details

CC-Link/LT

CC-Link/LT is an open network in the open network CC-Link family designed to reduce wiring in the cabinet and the machine.
Also, FX3UC-32MT-LT(-2) has CC-Link/LT master functionality built-in, so reduced wiring network can be easily achieved.

Details

N:N network

This network connects multiple FX PLCs (maximum 8 units) and performs automatic data exchange between each PLC. Linked devices are exchanged between each PLC, and all connected PLCs can share (monitor) linked devices.

Details

Parallel Link

Bit devices (M) and word devices (D) automatically refresh.

Details

Computer Link

A computer as master can connect to FX series as slave.
Supports "computer link protocol formats 1 and 4" on the computer side.

Details

Non-Protocol Communication

Non-proocol serial communication is possible to devices with RS-232C or RS-485 (422) communication interface (PC, barcode reader, etc).

Details

Peripheral device communication

PC, GOT, and HPP can connect to RS-232C/RS-422/USB (USB can be used by PC only) and perform PLC program transfer and monitoring.

Details

inverter communication

Mitsubishi inverter prococol and dedicated instructions for communication control are built into FX3 series PLC. Mitsubishi inverters can be easily controlled just by adding an RS-485 communication device.

Details

More Products